To order WEB STOCKED items: visit www.BenshawExpress.com
4 - 5
Standard Low Voltage Starter Products
Intelligent Motor Control
mx
2
controller
CONTROL FEATURES
Multiple Starting Modes:
• Voltage ramp
• Current ramp
- Adjustable initial current
- Adjustable maximum
current
- Adjustable ramp time
• Torque ramp (True Torque)
- Adjustable initial torque
- Adjustable maximum
torque
- Adjustable ramp time
• Power ramp
- Adjustable initial torque
- Adjustable maximum
torque
- Adjustable ramp time
• Linear/tach feedback
control
• Jogging 7 and 14%
speed
Motor Protection:
• Motor thermal overload
• Independent starting and
running OL’s
• Up to speed timer
exceeded
• Low line voltage
• Low line frequency
• High line frequency
• Phase reversal
• Phase loss
• Instantaneous overcurrent
• Overcurrent
• Undercurrent
• Current imbalance
• Ground fault residual
• Shorted SCR
• Disconnect fault
• Inline contactor fault
• Control power low
• Stack over temperature
Metering:
• +/- 2% accuracy
• Average current
• L1 current
• L2 current
• L3 current
• Current imbalance %
• Ground fault amps/
residual
• Average volts
• L1 – L2 voltage
• L2 – L3 voltage
• L3 – L1 voltage
• Overload %
• Power factor
• Watts
• VA
• VARS
• KW hours
• MW hours
• Phase order
• Line frequency
• Analog input
• Analog output
• Run time — days
• Run time — hours
• # of starts
• Tru Torque %
• Power %
• Peak starting current
• Last starting duration
3 Digital Inputs
Configurable to:
• Stop
• Fault
• Fault reset
• Bypass/confirmation &
inline
• OL reset
• Local/remote selection
• Heater enable
• Heater disable
• Dual ramp selection
• 1 dedicated start input
• 1 dedicated bypass
3 Relay Outputs
Configurable to:
• Starter off
• Faulted fail safe and non
fail safe
• Running
• Up to speed
• Alarm condition
• Ready condition
• Locked out
• Over current trip
• Under current trip
• OL alarm
• Shunt trip fail safe and
non fail safe
• Ground fault
• Energy saver indication
• Heating indication
• Slow speed forward/
reverse
• DC braking
• Cooling fan
• 1 fixed bypass
1 Analog 4 – 20 mA /
0 – 10 Vdc Input
Configurable to:
• Trip high level
• Trip low level
1 Analog 4 – 20mA
/ 0 – 10Vdc Output
Configurable to:
• Current
(0 – 200%/0 – 800%)
• Voltage (0 – 150%)
• OL (0 – 150%)
• kW (0 – 10 kW/0 – 100 kW)
• MW (0 – 1 MW)
• Analog input (0 – 100%)
• Firing (0 – 100%)
• Calibration
User Interface:
• Standard board-mounted
LED interface
• Optional remote mount
LCD display
- Set/examine operating
parameters
- View status information
- View line current,
voltage and frequency
in real time
- Start and stop the solid
state starter
1 Communication Port:
• ModBus / RS485
Advanced Functionality:
• Dual ramp selection
• Adjustable kick current
• Programmable decel
modes
• LV BIST test (built-in
self test)